welcome to Safelectron(Shenzhen) Co.,Limited
About
SAFELECTRON(SHENZHEN) CO.,LIMITED
SAFELECTRON (SHENZHEN) CO.,LTD is a professional manufacturer of cables and network keystone jacks& patch panels. Brands under its flag brand including "SAFELECTRON" , "TYUMEN", "AOTORUA" & "ZARIVY" Our company establish 2 factories in China, one for Cables and other factory speicial for Patch Panels & Keystone jacks. Cable range including: RG59, RG59+2DC wires, RG58, RG6, RG11, RG8, RG174, RG213, RG214; alarm cable, contron cable, fire alarm cable , Cat5e, Cat 6, cat7 and cat8 network cable, patch cord, Audio Cable , Telephone wire and power cable, UL2464 Cable.and so on. Network accessories&components Including: Keystone jack, patch panel ,cable manager, tools and all kinds of connectors like DC plug, BNC, RCA, RJ11/RJ45 plugs...etc. Safelectron develops and produces high quality security equipments and various types cable to meet market demand. We have passed CCC certificate, ISO 9001(2008) quality management system, CE certificate, RoHS certificate ,FCC certificate.and UL certificate. Safelectron's mission is helping customer to achieve their greatest value through our quality products and service. We sincerely hope Safelectron become your preferred and premium business partner.
View More
4577
4577
Success case
150
150
Global Locations
99
99
%
Customer praise
Product Categories

SAFELECTRON was founded in 2009, we establish 2 factories in China,
one for Cables and other factory speicial for Patch Panels & Keystone jacks. 

Fire,Alarm,Fire alarm,fire alarm cable,security
View More
2C Fire Alarm Cable 1.5mm Unshielded

2 Core Unshielded Fire Alarm Cable 2*1.5mm

RG59 Combo cable RG59+2C/20AWG
View More
RG59+2C*16/0.2mm CCA

RG59 Combo cable RG59+2C/20AWG

Cat8,10G,40Gbps,S/FTP
View More
S/FTP Cat8 Cable 10G 40Gbps

Cat8 Ethernet patch cable transmission rate up to 40Gbps. The range of Application:Perfect for Network Adapters, Hubs, Routers, DSL/Cable Modems, PS3, PS4, X-box, Patch Panels And Other High-Performance Networking Applications.

control,alarm,armored,cable
View More
ARMORED Control Cable

Rated voltages from 1 kV (Um=1.2 kV) up to 30 kV (Um=36 kV) - Part 1: Cables for rated voltages of 1 kV (Um=1.2 kV) and 3 kV (Um=3.6 kV)

CAT7,NETWORK,CABLE,10G,FTP,SFTP
View More
Cat7 Network Cable 10G, 1000MHz S/FTP

S/FTP-CAT7 10Gb, UTP, 23AWG, Solid Bare Copper, 8-Conductor UTP, U/FTP, F/FTP, S/FTP

Cat6a,F/FTP,S/FTP
View More
CAT6a 23AWG 4 Pair Ethernet Cable

CAT6a, 10Gbps, 23AWG Solid Bare Copper, 8-Conductor, 650MHz/ 750MHz, U/FTP, F/FTP, S/FTP

FTP,CAT6,OUTDOOR,SHIELD
View More
FTP CAT6 Cable Dual Jacket Outdoor Shield UV Resistance

FTP-CAT6 23AWG, Dual Jacket (PVC+PE, PVC+PVC), 4 Pairs

alarm,control,unshield
View More
12 Core Security Alarm Control Cable

Control Cable 12*0.22 Unshielded

FTP CAT5e/Cat6 Patch Panel 24Ports 0.5U/19inch
View More
FTP Cat6 24Ports 0.5U/19inch

0.5U/19inch FTP Cat5e/Cat6 Patch Panel 24-Port High-Density Shielded

Brush Panel
View More
Brush Panel 1U/19inch

The horizontal cable management panel with brush provides easy access to cables. The steel construction and black powder coating finish provides durability, and keeps the rack looking smooth and neat.

FTP CAT6A 24PORTS 1U/19inch
View More
24Ports FTP Cat6A / Cat7 1U/19inch

FTP CAT6A, cat7 24PORTS 1U/19inch 24 Port Shielded Patch panel load with 24 jacks. It can be equipped with 19inch racks and cabinets. It's ideal for 10/100/1000Base-T and 10G Base-T Ethernet applications. The detachable rear strain relief bar organize the cables orderly and neatly

24ports UTP Cat5e Patch Panel 1u/19
View More
24ports UTP Cat5e Patch Panel 1U

1U/19inch standard size for mounting into server racks and cabinet This patch panel is designed for 22-26 AWG solid conductors Ports: : 1U (12 , 16 and 24 ports)

UTP Cat6 Patch Panel 48Ports 2U/19inch
View More
48Ports UTP Cat6 2U/19inch

The unshielded modular Patch Panel is 2U 48 port that can be mounted into 19" racks and cabinets.Front frame with paper label transparent holder for different port identification. Back with T568A/B wring scheme for easy and fast termination. Double back bar for more cable management

48port FTP CCAT6 1U/19inch
View More
FTP Cat6 48Ports 1U/19inch

1U/19inch standard size for mounting into server racks and cabinet This patch panel is designed for 22-26 AWG solid conductors Height: 1U (48 ports)

UTP Cat6 Patch Panel 48Ports 1U/19inch
View More
UTP Cat6 48Ports 1U/19inch

1U 48 port patch panel is high density modular loaded patch panel.it can be used in confined spaces or small equipment room for maximum wiring.The patch panel is 90 degree punching direction with wide cable management rear bar.

UTP Cat6 Patch Panel 24Ports 1U/19inch
View More
UTP Cat6 24Ports 1U/19inch

The unshielded patch panel is 8P8C modular 24 port in front and 110 punch down connector blocks on the back .The Ethernet patch panel is designed for use in 19” racks and ideal for 10/100/1000Base-T and 10GBase-T Ethernet applications.The paper label with clear numbers for cable identification. The rear bar enables quick and easy cable management.

FTP Cat6A Keystone Jack
View More
FTP Cat6A Keystone Jack

The shielded toolless keystone jack is crocodile style with 180 degree punching.Fully shielded zinc alloy design prevents the signal leak and interference. Tool-less needs no more punching tool for termination

FTP CAT6A /CAT8 Keystone jack
View More
FTP CAT6A /CAT8 Keystone jack

SHIELDED KEYSTONE JACK FOR CAT8 CABLE

FTP Cat6A Keystone Jack 3M Type
View More
FTP Cat6A Keystone Jack 3M Type

The shielded toolless keystone jack is crocodile style with 180 degree punching.Fully shielded zinc alloy design prevents the signal leak and interference. Tool-less needs no more punching tool for termination

SHIELDED KEYSTONE JACK FOR CAT6A & CAT8 CABLE
View More
FTP CAT6A/CAT8 Keystone Jack New

SHIELDED KEYSTONE JACK FOR CAT6A & CAT8 CABLE

FTP CAT6 RJ45-RJ45 Coupler Female
View More
FTP CAT6 RJ45-RJ45 Coupler Female

The RJ45 In-line coupler is female to female connection that can be used in various applications.It can be installed easily in data center and cabling room and area cabling applications.It guarantee the CAT6 and Cat6A shielded performance

cat6,cat6a
View More
UTP Cat6 Keystone Jack Toolless

This toolless keystone jack comes with concise and compact design. The toolless means not having punching tool for termination,fast and easy installation. It supports both T568A/B wiring . The color label on the cap is visible for guiding. The jack meets Cat6A standard , also compatible with lower classes like CAT6.5E

UTP cat5e/cat6/cat6a Keystone Jack Toolless
View More
UTP cat5e/cat6/cat6a Keystone Jack Toolless

This toolless keystone jack comes with concise and compact design. The toolless means not having punching tool for termination,fast and easy installation. It supports both T568A/B wiring . The color label on the cap is visible for guiding. The jack meets Cat6A standard , also compatible with lower classes like CAT6. also Cat5e.

Cat5e/Cat6/Cat6A  RJ45 F/F Coupler
View More
Cat5e/Cat6/Cat6A RJ45 F/F Coupler

The RJ45 In-line coupler is female to female connection that can be used in various applications.It can be installed easily in data center and cabling room and area cabling applications.It guarantee the Cat5e,CAT6 and Cat6A shielded performance

DC,DC POWER,DC MALE,DC PLUG
View More
DC Male Plug Green

2.1mm x 5.5mm Male CCTV Camera DC Power Adapter Connector

DC,FEMALE,PLUG,CONNECTOR,12V
View More
DC Female Plug Green

Female 2.1x5.5mm DC Power Cable Jack Adapter Connector Plug Led Strip CCTV Camera Use 12V

dc plug,dc connector,dc male,DC,BNC
View More
DC Male Plug Press Terminal

DC Male Plug Press Terminal

bnc male,bnc,dc,dc connector,dc plug
View More
BNC Male Connector to DC

BNC Male Plug to 2 Pin/Way Press Terminal

DC,DC POWER,DC CONNECTOR,DC FEMALE
View More
DC Male Connector Press Terminal

Female 12V 2.1 x 5.5mm DC Power Jack Plug Spring Press Adapter Connector for CCTV Camera and LED Strips

BNC,RG59,COAXIAL,CONNECTOR,75OHM
View More
RG59 BNC Connector Welding Free

BNC Male Coaxial Connectors Free Soldering with Screw and Spring Brass Adapter

RG59,COAXIAL,BNC,CONNECTOR,FEMALE
View More
BNC Coupler Female to Female

BNC Female to Female Coupler

bnc,rg6,connector,coaxial
View More
Compression BNC RG6

BNC Compression Connector for RG6 Coaxial Cable

BNC+DC Camera Cable 20m White
View More
BNC+DC Camera Cable 20m White

This cable can make from 5 meters to 50 meters. This pre-terminated CCTV cable is perfect for transmitting audio video and power. Simplify the installation of surveillance systems by using one cable to carry audio video and power

HD,8MP,50 meters,coaxial,siamese,All in One
View More
HD CCTV Camera Cable Coaxial Type

Cable Length : 5m/10m/15m/20m/30m/40m/50m . This pre-terminated CCTV cable is perfect for transmitting audio video and power. Simplify the installation of surveillance systems by using one cable to carry audio video and power. The cable can connect to 720P, 960P, 1080P, 700TVL,1000TVL,1200TVL, HD-CVI, HD-TVI, HD-AHD HD-SDI 960H Security Cameras without interference or quality decrease. ● Premade Coaxial+Power Siamese Cable ● The inner conductor of coaxial (Video) cable is pure copper ● 2.1mm * 5.5mm DC power plug ● Transmit video signals and supply DC power for security cameras ● Compatible with 960H, AHD 720P/960P/1080P, HDCVI/HD-TVI/HD-SDI

COAXIAL,CABLE,STRIPPER,TOOL
View More
Coaxial Cable Stripper Tool

Coaxial Cable Stripper Tool

LAN,NETWORK,CRIMPING,TOOL,TESTER
View More
Networking Crimping Tool with Tester

Network Cable Crimper Pliers LAN Ethernet 6P 8P Crimping Network Testers

CAT5E,CAT6,RJ45,CRIMPING,TOOL
View More
RJ45 EZ Pass Crimp Tool

RJ45 Cat5e Cat6 Connector Crimping Tool

RJ45,CRIMPING,TOOL,NETWORK,LAN
View More
RJ45 CAT5e, CAT6, CAT6A, CAT7 Crimping Tool

RJ45 Crimp Tool

COAXIAL,TOOL,COMPRESSION,F CONNECTOR
View More
Coax Compression Tool RG59 RG6 F BNC RCA

Coax Compression Tool RG59 RG6 F BNC RCA

Coaxial,RG174,RG59,RG6,Crimp Tool
View More
Coaxial Crimp Tool RG174, RG58, RG59, RG6

Coaxial Crimp Tool RG174, RG58, RG59, RG6

Our Solution

We focus on creating the absolute best customer service experience and provide the highest quality products. With more than 15 years experience, we are able to understand your requests and clearly convert them to make your best products.

BNC+DC Camera Cable Pre-made
BNC+DC Camera Cable Pre-made
What is cat5E patch panel
What is cat5E patch panel
The distribution frame is the most important component in the floor management room system, and it is the hub that realizes the cross-connection of the two subsystems, the vertical trunk line and the horizontal wiring. Patch panels are usually installed on cabinets or walls. Category 5 distribution frame mainly refers to the distribution frame that specifically meets the gigabit transmission performanceCategory 5 distribution frames are mainly used for gigabit networks. Manufacturers advocate them. Now they are also commonly used in local area networks because they are not much more expensive than Category 5 cables. The current Category 6 distribution frames are generally used for ATMs. In the network, the company LAN is not recommended for the time being. At present, the common type of super five or six patch panels in general LANs, especially the current super five and six patch panels can easily provide 155Mbps communication bandwidth, and has the potential to upgrade to gigabit bandwidth, so , Has become the first choice for today's horizontal wiring. The patch panel can be divided into: shielded patch panel and unshielded patch panel. Most local area networks use unshielded patch panel (UTP—Unshielded Twisted Pair) as the transmission medium of wiring for networking.
How To Connect The Network Cable RJ45 Plug,Module And Patch Panel?
How To Connect The Network Cable RJ45 Plug,Module And Patch Panel?
RJ45 PlugThe method of connecting the crystal head has been posted many times in previous articles. Generally, it is crimped according to the line sequence of T568B: orange white-orange-green and white-blue-blue and white-green-brown and white-brown, arrange the lines The order of the cores, after cutting flat, insert the cores side by side into the crystal head according to the upward direction of the crystal head chip, and then put it into the 8P port of the network cable pliers, and press it.Tools: Use ordinary network cable pliers for Category 5 and Category 6, and special network cable pliers for Category 7 cables. No need to use the network cable pliers without crystal plug.2. ModuleThere are two ways to connect to the module, T568A and T568B. Generally, the T568B wire sequence is used for crimping. After the grooves are matched, use a wire cutter to punch the wire.When connecting the module, it is necessary to ensure a unified standard, which is the same as the crystal head, and there are numbers from 1 to 8 in the logo, which must be sorted in numerical order and then crimped.Tools: wire punching knife, no punching type module does not need to use wire punching knife.3. Distribution frameThe distribution frame also has two wiring methods, T568A and T568B, and the wiring method is also very simple. Take the six types of network cables as an example:Use a wire stripper to remove the outer cover and cross frame of the network cable;Then insert the core of the network cable into the card slot of the corresponding wire sequence;Then buckle the cable management ring into the slot and fix it with a cable tie to prevent it from falling off;Finally, install the distribution frame on the cabinet with cabinet screws.PS: The connection method of the patch panel is similar to that of the module, but the label of the wire sequence will be different for patch panels of different brands, so please pay attention to it when connecting.
How to install Cat5e/Cat6/Cat6a Toolless Keystone Jack?
How to install Cat5e/Cat6/Cat6a Toolless Keystone Jack?
This toolless keystone jack comes with concise and compact design. The toolless means not having punching tool for termination,fast and easy installation. It supports both T568A/B wiring . The color label on the cap is visible for guiding. The jack meets Cat6A standard , also compatible with lower classes like CAT6.5E●Toolless without having punching tool for termination●Dual-color-coded Labeling for 568A/B (258A) Wiring Schemes●It compatible with standard wall plate, blank patch panel
Need high quality products with good prices and services?
Latest News

view more
What Is Patch Panel ?
Jul20
What Is Patch Panel ?

Used for end user lines or trunk lines, and can be deployed and connected to the equipment. The distribution frame is the most important component in the management subsystem, and it is the hub that realizes the cross-connection of the two subsystems, vertical trunk line and horizontal wiring. Patch panels are usually installed on cabinets or walls. By installing accessories, the distribution frame can meet the needs of UTP, STP, coaxial cable, optical fiber, audio and video. The distribution frames commonly used in network engineering include twisted pair distribution frames and optical fiber distribution frames. According to the place of use and purpose, it is divided into two categories: main distribution frame and intermediate distribution frame.

View More
  • {$vo.title
    May23
    2022 NEW Tool-less Shielded Keystone Connector

    It will be our 2022 new released product The product is combined with RJ45 keystone and RJ45 plug for easy and fast connection The shielded provide better performance, without tool to punch or crimp the cables

    View More
  • {$vo.title
    May23
    Introduction To Patch Panel

    The main distribution frame, referred to as MDF, is used to connect subscriber lines, trunk lines, and dedicated lines to the corresponding interface points of the telephone exchange for testing, wiring, and protection of internal equipment.The structure of MDF is divided into two sides, in-line and in-line. In-line can be installed and guaranteed, and the test row or wiring is installed in horizontal. For in-line trunk lines or dedicated lines that do not need protection, test racks or wiring bars can also be installed. The main distribution frame of the same model can be spliced to meet the needs of expansion. The main distribution frame of the subscriber exchange adopts the box type because of its small capacity. In the early days, the total distribution frame was large, with a maximum capacity of 303 loops per line. The security guard adopts 20-wire or 21-wire carbon lightning arrester and uses a hot coil to limit the current. The test row is 20 lines and adopts a four-line shrapnel type, and the lead-in and lead-out lines can be separated by separating the shrapnel. The new type main distribution frame is matched with the program-controlled switchboard to greatly reduce the size and weight, and each in-line can accommodate 1,000 lines. Ensure to arrange 100 loops per block, and use metal discharge tubes to prevent high voltage and overcurrent. Each test row has 128 lines, and the contact reeds can be separated, so that the lines can be easily separated for testing. The wires connected to the terminals have their own independent wire troughs, which are easy to install and maintain. The guarantee arrangement adopts the card connection method to connect, and the insulation layer of the wire does not need to be stripped when the card is connected. The test row adopts winding method for wiring. Both of these two wiring methods are simple, reliable, fast, and non-polluting. According to different occasions, the new type of distribution frame has wall-mounted, floor-standing, single-sided and double-sided types.The main functions of the main distribution frame are: ①Security function. It protects the subscriber line against high voltage or high current; ②wiring. Any user can choose the number in the office, and the trunk lines between different offices can choose to occupy the trunk modules in the office, and can connect the inter-office and related subscriber lines according to the needs of the dedicated line.Intermediate distribution frame, referred to as IDF, is a distribution frame that connects the incoming and outgoing lines between the internal telephone exchanges. According to its installation location, it can be divided into two types: the main distribution frame and the intermediate distribution frame of the switching equipment and the inter-machine distribution frame.The structure of IDF is also divided into two sides, in-line and horizontal, in-line connection of the equipment's outgoing line, and horizontal connection of the equipment's incoming line. Both in-line and horizontal lines are equipped with wiring strips. One side of the improved terminal block is winding. The other side is the wire bonding. The function of IDF is mainly to deploy the access lines between all levels of switching equipment in order to give full play to the role of all levels of switching equipment.

    View More
  • {$vo.title
    May23
    How To Connect The Network Cable To The Crystal Plug, Module And Patch Panel?

    1. Crystal headThe method of connecting the crystal head has been posted many times in previous articles. Generally, it is crimped according to the line sequence of T568B: orange white-orange-green and white-blue-blue and white-green-brown and white-brown, arrange the lines The order of the cores, after cutting flat, insert the cores side by side into the crystal head according to the upward direction of the crystal head chip, and then put it into the 8P port of the network cable pliers, and press it.Tools: Use ordinary network cable pliers for Category 5 and Category 6, and special network cable pliers for Category 7 cables. No need to use the network cable pliers without crystal plug.2. ModuleThere are two ways to connect to the module, T568A and T568B. Generally, the T568B wire sequence is used for crimping. After the grooves are matched, use a wire cutter to punch the wire.When connecting the module, it is necessary to ensure a unified standard, which is the same as the crystal head, and there are numbers from 1 to 8 in the logo, which must be sorted in numerical order and then crimped.Tools: wire punching knife, no punching type module does not need to use wire punching knife.3. Distribution frameThe distribution frame also has two wiring methods, T568A and T568B, and the wiring method is also very simple. Take the six types of network cables as an example:Use a wire stripper to remove the outer cover and cross frame of the network cable;Then insert the core of the network cable into the card slot of the corresponding wire sequence;Then buckle the cable management ring into the slot and fix it with a cable tie to prevent it from falling off;Finally, install the distribution frame on the cabinet with cabinet screws.PS: The connection method of the patch panel is similar to that of the module, but the label of the wire sequence will be different for patch panels of different brands, so please pay attention to it when connecting.

    View More
Porject Cases

Leave A Message
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact

0.080329s